ARTS ENERGY

A battery to fit every application, specification and need

Ni-Cd batteries

Ni-Cd battery Standard & High Energy
VRE series
ARTS Energy VRE standard Ni-Cd series were originally designed for cycling applications requiring a rapid charge. However, they are also suited for a wide range of applications where they offer an excellent
cost / performance ratio. The high level of reliability provided by ARTS Energy’s standard series is time tested and well-proven, with hundreds of millions of units delivered over years. ARTS Energy’s VRE high energy Ni-Cd series
benefit from significant technological upgrades compared with standard series. The VRE design features advanced nickel foam electrode technology to meet the fast charge and increased capacity needs of light and compact equipment.
ARTS Energy VRE standard Ni-Cd series were originally designed for cycling applications requiring a rapid charge.
However, they are also suited for a wide range of applications where they offer an excellent cost / performance ratio.
The high level of reliability provided by ARTS Energy’s standard series is time tested and well-proven, with hundreds of millions of units delivered over years. ARTS Energy’s VRE high energy Ni-Cd series
benefit from significant technological upgrades compared with standard series. The VRE design features advanced nickel foam electrode technology to meet the fast charge and increased capacity needs of light and compact equipment.
  Building &
Industrial plants
Emergency &
Security systems
Professional
mobility
Professional
tools
Professional
electronics
Medical Military &
defence
Marine Small off-grid
PV applications
Telecom-
munications
VRE        
VT              
VNT                
VNT U                

VRE
SERIES

  • Professional tools
  • Professional electronics
  • Medical
  • Telecommunications
  • Military & defence
  • Marine
  • Telecommunications
  ARTS Energy type IEC capacity at 0.2C rate Standard
charge (16h)
Quick or Fast charge Typical Internal
impedance
Max. dimensions
for bare cells
Typical
weight
Data
sheet
Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Current
[mA]
Current
[mA]
Time
[h]
[m0hm] Diameter
[mm]
Height
[mm]
[g] Download
VRE VRE AA 700 AA 780 700 70 700 1 14 14 49.3 21
VRE Cs 1600 Cs 1600 1500 150 1500 1 5 22.2 42.2 48
VRE Cs 1800 Cs 1800 1700 170 1700 1 5 22.2 42.2 49
VRE C C 2550 2300 230 2300 1 5 25.3 49.5 75
VRE D D 5100 4500 450 4500 1 4 32.2 58.6 / 60.3 140
VRE D 5500 D 5500 5000 500 5000 1 4 32.2 58.6 150
VRE F F 8800 8000 800 8000 1 4 32.2 89.2 220
  ARTS Energy type IEC capacity at 0.2C rate Data
sheet
Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Download
VRE VRE AA 700 AA 780 700
VRE Cs 1600 Cs 1600 1500
VRE Cs 1800 Cs 1800 1700
VRE C C 2550 2300
VRE D D 5100 4500
VRE D 5500 D 5500 5000
VRE F F 8800 8000

VT
SERIES

  • Building & industrial plants
  • Emergency & security systems
  • Medical
  ARTS Energy type IEC capacity at 0.2C rate Standard
charge (16h)
Quick or Fast charge Typical Internal
impedance
Max. dimensions
for bare cells
Typical
weight
Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Current
[mA]
Current
[mA]
Time
[h]
[m0hm] Diameter
[mm]
Height
[mm]
[g] Download
VT VT F F 7500 7000 700 350 - 5 32.2 91.1 196
VT F 70 F 7700 7000 700 350 - 5 32.2 89.2 196
  ARTS Energy type IEC capacity at 0.2C rate Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Download
VT VT F F 7500 7000
VT F 70 F 7700 7000

VNT
SERIES

  • Building & industrial plants
  • Emergency & security systems
  ARTS Energy type IEC capacity at 0.2C rate Standard
charge (16h)
Quick or Fast charge Typical Internal
impedance
Max. dimensions
for bare cells
Typical
weight
Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Current
[mA]
Current
[mA]
Time
[h]
[m0hm] Diameter
[mm]
Height
[mm]
[g] Download
VNT VNT CS Cs 1650 1600 160 80 - 8 22.2 42.2 45
VNT D D 4250 4000 400 200 - 6 32.2 60.3 115
  ARTS Energy type IEC capacity at 0.2C rate Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Download
VNT VNT CS Cs 1650 1600
VNT D D 4250 4000

VNT U
SERIES

  • Building & industrial plants
  • Emergency & security systems
  ARTS Energy type IEC capacity at 0.2C rate Standard
charge (16h)
Quick or Fast charge Typical Internal
impedance
Max. dimensions
for bare cells
Typical
weight
Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Current
[mA]
Current
[mA]
Time
[h]
[m0hm] Diameter
[mm]
Height
[mm]
[g] Download
VNT U VNT CS U Cs 1650 1600 160 80 - 8 22.2 42.2 45
VNT C U C 2650 2500 250 125 - 8 25.3 49.5 75
VNT D U D 4250 4000 400 200 - 6 32.2 60.3 115
VNT D U HC D 4500 4200 420 200 - 6 32.2 60.3 124
  ARTS Energy type IEC capacity at 0.2C rate Data
sheet
  Nominal voltage
1.2 volts/cell
Size Typical
[mAh]
Minimum
[mAh]
Download
VNT U VNT CS U Cs 1650 1600
VNT C U C 2650 2500
VNT D U D 4250 4000
VNT D U HC D 4500 4200

Contact Us

Unit 1310, Asia Trade Centre, 79 Lei Muk Road, Kwai Chung,
New Territories, Hong Kong

Tel: 852-2708 4682    Fax: 852-2389 7896
E-mail: info@ellan.com.hk